Gypsum Board* — Any 5/8 in. thick UL Classified Gypsum Board that is eligible for use in Design Nos. L501, G512 or U305. Nom. 5/8 in. thick, 4 ft. wide, applied vertically, and nailed to studs and bearing plates 7 in. OC. with 6d ... Fire-resistance Ratings - ANSI/UL 263 See General Information for Fire-resistance Ratings - ANSI/UL 263 Design ...Find a Nonprofits web design agency today! Read client reviews & compare industry experience of leading Nonprofits web design companies. Development Most Popular Emerging Tech Deve...Oct 9, 2023 · For shafts that do not extend to the underside of the roof sheathing, a horizontal membrane is required with the same fire rating as the shaft enclosure. Reference pages 67 and 68 of The Wood Book for 1-hour membranes using UL design I504 and pages 75 and 79 for 2-hour membranes with UL design I516. Are penetrations permitted in shaft enclosures? Try Figma for free. Create beautiful user interfaces with our UI design tool. Collaborate on creations, build prototypes & create seamless workflows all-in-one. Get started today.Detail No. Title UL Design Head of Wall Firestop System Page SW Series - Shaftwall Assemblies 09 21 16.23 1 Hour Shaftwall Partition to Steel Beam 1 Hour Shaftwall Partition Offset from Beam SW 102 SW 103 U499, W419 U499, W419 U499, W419 U499, W419 SW 104 SW 105 1 Hour Shaftwall with Deflection Track 1 Hour Shaftwall with Deflection Track

UL DESIGN I504 - A 1-hour horizontal assembly that consists of 3 ⅝" steel studs 16" o.c. with three layers of ⅝" Type X (Gold Bond XP ® Fire-Shield ®) gypsum board on the …

Return to results :: Keyword: "I504" Wallboard. UL Certified. DOCUMENT: CKNXC.R2717 · Product Code (UL CCN): CKNXC The document listing is represented by a combination of the UL CCN and File Number. A UL CCN (Category Control Number) is the code that represents the Product Category (Category Description). See below for more info on …

It combines data from many legacy UL solutions, including the Online Certification Directory, Product Spec and several iQ databases into one streamlined experience. A free Product iQ account helps users verify UL certification of products and components, locate UL Solutions guide information and search for alternative certified products.1. UL tests rate an entire assembly. No ceiling or suspension system product alone constitutes a fire-rated assembly. 2. You can use only the specific type, size, and minimum thickness of Fire Guard™ ceilings or suspension system identified in each assembly. 3. This table is a guide. (See UL Fire Resistance Directory for complete design details). UL fire resistance ratings are based upon the test method and acceptance criteria in the ANSI/UL263 (ASTM E119) Standard for Fire Tests of Building Construction Materials. Underwriters Laboratories and their Fire Resistance directory should be consulted for conplete up-to-date details when specifying a design. ULPRF: Get the latest ULS Group stock price and detailed information including ULPRF news, historical charts and realtime prices. Indices Commodities Currencies StocksWe would like to show you a description here but the site won’t allow us.

The UL measurement is a symbol used by the International System of Units to represent a microliter. A microliter is a metric unit of measurement for liquid volume and is equal to 1...

Looka Logo Maker combines your logo design preferences with Artificial Intelligence to help you create a custom logo you'll love. All it takes is a few clicks and five minutes. Let's make a logo! 01. Our logo maker is easy. Start by entering your company name and industry, then select the perfect logo styles, colors, and symbols that you like ...

See when UL Solutions received your product samples, when they are returned, picked up, destroyed or archived. Documents. Search, View, and download your UL Solutions reports, procedures and global certifications. Browse documents and associated supplements. Download multiple documents at once.Design Studio Design Studio. Wall Assemblies; Floor-Ceiling Assemblies; Roof-Ceiling Assemblies; Design Details; Shaft Wall Limiting Heights & Spans; Competitor Comparison Tool; USG Sustainability Tool; USG Ceiling Technix™ Virtual Acoustics Experience™ (VAE) USG Assembly Builder™ All Design StudioDesign Studio. Find the right fire-rated assemblies and design details drawings for your architectural plans. Estimate materials and find USG equivalents for your building projects. More. Find Your Architectural Rep. Architectural …The UL Certification Mark on exterior wall assemblies is relied on by code enforcement officials and buyers to provide confidence that products and systems meet regulatory and market requirements and is a key differentiator for products within the exterior wall assembly market. The UL Evaluation Report, an additional differentiator, provides ...The new UL Design W404 consists of an exterior wall assembly that is constructed of the most common metal building structural components. The exterior metal cladding and interior sides were both subjected to separate one-hour fire tests, as well as hose stream tests immediately following each burn. The fire tests determined the UL … Each UL design outlines the required components and acceptable alternatives. The itemized product descriptions indicate if fire taping is required. Reference U305 (bearing wall) Item #2, V438 (nonbearing wall) Item #8 and W469 (bearing wall) Item #9: “Paper tape and joint compound may be omitted when gypsum panels are supplied with a square ...

UL FIRESTOP PENETRATION NUMBERING (Tested to UL 1479 Inspect to ASTM E-2174) SYSTEM First Alpha Character Letter Description C Systems intended to protect penetrations through either floors or walls F Systems intended to protect penetrations through floors W Systems intended to protect penetrations through walls ...Products. Fire resistance is an important consideration for every ceiling system - no matter how simple or complex. Our fire resistant ceiling tiles are engineered to meet the most stringent industry standards. Select fire …It combines data from many legacy UL solutions, including the Online Certification Directory, Product Spec and several iQ databases into one streamlined experience. A free Product iQ account helps users verify UL certification of products and components, locate UL Solutions guide information and search for alternative certified products.Document 481007 Horizontal Mount Damper in Non Concrete Barrier DFD, FD, and FSD Series. These instructions apply to 11⁄2 hour rated Greenheck combination fire smoke dampers and fire dampers mounted horizontally in design I503 as detailed in the UL Fire Resistance Directory. UL design I503 is a 2 hour rated non-load bearing horizontal …Method (e.g., Working Stress Design Method). For jurisdictions employing the Limit States Design Method, such as Canada, a load restriction factor shall be used — See Guide BXUV or BXUV7 * Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively.Otherwise check out UL-I504 and I-501, they may or may not work in your application as the requirements are complex, very specific yet somewhat vague. Note: I don't have any …A: Yes, fire-rated roof-ceiling assemblies that include resilient channels and loose-fill insulation are a common option that allow insulation to rest directly against …

The most comprehensive house siding resource on the web. Explore siding options, types, and design ideas for every siding material available today. Expert Advice On Improving Your ...

For 1-hour assemblies National Gypsum developed UL design I504 which is a 1-hour horizontal assembly that consists of 3-58 steel studs 16 oc. Ul Design K504 122 PDF Ul Design K504 The Gypsum Construction Handbook-RSMeans 2009-01-03 One of the construction industrys longest-running most relied-on references The Gypsum …You have been logged out. You have been logged out due to inactivityBest Job Ever: AWCI Contractors Reveal Their Best Work. Rob Aird, C. Brent Allen, Lee Zaretzky, Davis Sprague and Travis Vap share a passion for transforming spaces and structures with an eye for craftsmanship, innovation …three layers 5/8" thick gypsum board (ul type ulix™) assembly options: ul design no. i506 b notes: for the most up-to-date information or assembly options, refer to the ul fire … See General Information for Fire-resistance Ratings - ANSI/UL 263 Certified for United States Design Criteria and Allowable Variances See General Information for Fire Resistance Ratings - CAN/ULC-S101 Certified for Canada Design Criteria and Allowable Variances Design No. U501 July 10, 2020 Nonbearing Wall Rating — 3 HR. In today’s competitive marketplace, building consumer confidence is crucial for the success of any business. One effective way to achieve this is by ensuring that your products mee...One-Hour Wall Membrane (Based on UL Design U 301) The membrane consists of two layers of 5/8” (15.9 mm) type X gypsum board directly applied to framing or furring. The base layer of gypsum board is applied either parallel or at right angles to wall or partition framing 16” (406 mm) o.c. and attached with 1” (25 mm) Type S or S-12 drywall ...

UL Fire Resistance Designs that are listed for conformity with Canadian requirements, and thereby bearing the cUL Mark, are identified as such in our Directories in two ways. First, the UL/ULC both use Category Code Numbers (CCNs) to identify product categories. Each category code in itself will provide full information for the Designs for that ...

For more information visit www.ul.com The fire-resistance rated wall assemblies published under the U, V and W series of designs on the UL Online Certifications Directory are intended for interior applications unless otherwise specified or implied in the design. There are two methods by which a wall design specifies or implies suitability

UL/cUL I514: This testing protocol provides a two-hour fire resistance rating, using a minimum 6”, 33 mil steel stud, four layers of 5/8” type C, with resilient channel between the third and fourth layer.For 1-hour assemblies National Gypsum developed UL design I504 which is a 1-hour horizontal assembly that consists of 3-58 steel studs 16 oc. Ul Design K504 122 PDF Ul Design K504 The Gypsum Construction Handbook-RSMeans 2009-01-03 One of the construction industrys longest-running most relied-on references The Gypsum …Find a Nonprofits web design agency today! Read client reviews & compare industry experience of leading Nonprofits web design companies. Development Most Popular Emerging Tech Deve...UL/cUL I514: This testing protocol provides a two-hour fire resistance rating, using a minimum 6”, 33 mil steel stud, four layers of 5/8” type C, with resilient channel between the third and fourth layer.It combines data from many legacy UL solutions, including the Online Certification Directory, Product Spec and several iQ databases into one streamlined experience. A free Product iQ account helps users verify UL certification of products and components, locate UL Solutions guide information and search for alternative certified products.Design No. I504 | PDF | Drywall | Framing (Construction) I504_20220719 - Free download as PDF File (.pdf), Text File (.txt) or read online for free. UL Details.UL Fire Resistance Designs that are listed for conformity with Canadian requirements, and thereby bearing the cUL Mark, are identified as such in our Directories in two ways. First, the UL/ULC both use Category Code Numbers (CCNs) to identify product categories. Each category code in itself will provide full information for the Designs for that ...Gypsum Board* — Any 5/8 in. thick UL Classified Gypsum Board that is eligible for use in Design Nos. L501, G512 or U305. Nom. 5/8 in. thick, 4 ft. wide, applied vertically, and nailed to studs and bearing plates 7 in. OC. with 6d ... Fire-resistance Ratings - ANSI/UL 263 See General Information for Fire-resistance Ratings - ANSI/UL 263 Design ... Elements of buildings the fire-resistance rating classifies the ability of an assembly to confine and isolate fire within a zone comprised of fire-resistance rated walls ceiling and floor assemblies. For 1-hour assemblies National Gypsum developed UL design I504 which is a 1-hour horizontal assembly that consists of 3-58 steel studs 16 oc. 608 ...

To answer this specific question, changes to a UL fire-rated design are permitted, such as reducing the stud spacing or increasing the thickness of the gypsum board. But for details about modifying a specific UL fire-rated assembly before specifying, talk with an excellent resource, your construction design manager. ... I504 | 1-hour …Mecca is where Abraham built the Ka’aba, and some believe he did so in order to rebuild the Bait-ul-Allah that had originally been built by Adam. This is the building that every Mu... Each UL design outlines the required components and acceptable alternatives. The itemized product descriptions indicate if fire taping is required. Reference U305 (bearing wall) Item #2, V438 (nonbearing wall) Item #8 and W469 (bearing wall) Item #9: “Paper tape and joint compound may be omitted when gypsum panels are supplied with a square ... Instagram:https://instagram. food restaurants open now near memhr wild dark leather10000 cad in usdswag female clothing Mar 2, 2022 · Design Criteria and Allowable Variances D e s i g n N o. V 4 4 9 M a rc h 2 , 2 0 2 2 Non-Bear ing Wall Rating - 2 hr. * Indicat es such pr oducts shall bear the UL or cUL Cer tification Mark for jur isdictions employing the UL or cUL Cer tification (such as Canada), r espectively. 1. and UL Fire Ratings The following table lists the USG panels that are appropriate to use for different UL fire-resistive Designs. USG Panels USG Panels USG Panels UL Design Number UL Design Number UL Design Number G503, G531, L501, L508, N501, N502, N505, P515, P516, U026, U301, U302, U303, U304, U305, U308, U314, U321, U329, … the beach 2000 imdbtimes union obits jacksonville fl GCP DESIGN SELECTION PROGRAM. This program is designed to assist the user in selecting the optimum GCP Applied Technologies Fire Resistance Design based on specific project criteria. It is intended for use in the US market and those markets that utilize the International Building Code (IBC). The program is not intended to provide Fire ... 24 hour pharmacy morgantown wv Figure 1.4.1: ASC STEEL DECK- UNDERWRITERS LABORATORIES (UL) FIRE RESISTANCE Figure 1.4.1: ASC STEEL DECK- UNDERWRITERS LABORATORIES (UL) FIRE RESISTANCE UL Design Number Minimum Beam or Joist Unrestrained Assembly Rating8 Minimum Concrete Reinforcing Fire Proofing2 On Restrained Assembly Rating8 …GCP Applied Technologies Inc., 2325 Lakeview Parkway, Suite 400, Alpharetta, GA 30009, USA GCP Canada, Inc., 294 Clements Road, West, Ajax, Ontario, Canada L1S 3C6