Joel - I tried to configure (imagine) a non-prestressed concrete tank that had H^2 / Dt > 50. Hard to do. For both the considerations of the combined shear + flexural demand at the base, and shrinkage, tall non-prestressed concrete tanks are uncommon, and I certainly would try to persuade you toward either steel or prestressed (DYK / DN) Type …See thread507-434895: Tension Field Action - End panels in Old Codes. BA. rb1957 (Aerospace) 7 Sep 20 22:16. the author makes the point that the end bays usually don't have the stiffener at the extreme end of the beam, and so the web cannot develop the shear buckles. In the example R13 posted these end panels aren't doing anything to react the ...GEE8B (Structural) 29 Apr 23 08:33. Dead load is always downward (direction of gravity). Wind load can be upward or downward (suction/pressure). Wind forces away from the surface are (-). Wind forces towards the surface are (+). So the “W” in 0.6D+W can be negative or positive. Pressure and suction values are typically per ASCE7, and it is ...Student posting in Eng-Tips forums for help with theses or coursework is forbidden. This is considered cheating. Offending posts will be removed from the site and offending members will lose their membership privileges. Posting. Commercial and/or recruiting "spam" will not be tolerated in the forums. Our forums are member-policed via the forums' "Red-Flag" …

Normally gauges and transmitters come in 1/2 " size. I've not seen many 1/2" flanges used. My standard is to have a flanged isolation valve ,1" often with a 2" tee off the main line and a reducer for mechanical integrity, with a tapped blank flange.Actuators are Rotork, valves are a well-known Western manufacturer. One of the actuators is sized at 100% of predicted valve operating torque. To me this instinctively feels incorrect - I made a few calls to friends elsewhere who both suggested actuators are normally capable of 150% - 200% of valve rated torque, …

Hi all, I'm designing a diesel tank 14m Diameter, 15m high tank with a fixed roof (rafters and roof plate). Max inlet flow rate = 870 m^3/h DN250 Max outlet flo

Electronics Packaging engineering. Fluid Power engineering. Gas compression engineering. Gas distribution engineering. Gear & Pulley engineering. Heat Transfer & Thermodynamics engineering. HVAC/R engineering. Ignition, Combustion and Detonation engineering. Laser engineering. HVAC/R engineering. (27384 members) forum403 - Professional forum and technical support for engineers for HVAC/R engineering. Includes problem solving collaboration tools. Search.Professional Ethics in engineering. (12071 members) forum765 - Professional forum and technical support for engineers for Professional Ethics in engineering. Includes problem solving collaboration tools. Forum. Search. FAQs. Links. MVPs.Qatar has for months been criticized for mistreating migrant workers. Qatar, one of the world’s richest countries and the winner of the bid to host the soccer World Cup in 2022, ha...

Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search …

Indian women are more educated than they have ever been. Yet, the latest figures show that fewer of them are working. Indian women are more educated than they have ever been. Yet, ...

As we lose the stable structure we’re used to, many of us are now experiencing symptoms of burnout. How can we overcome it? Humans are creatures of habit. We function best and feel... Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search Of All Posts, And More... Register now while it ... To Remove or insert a Spacer or Blind you first depressurize the System, Then make it Safe. Then you remove all the Bolts on One (1) side of the Flange set. Then you "Jack" the Flanges apart using the built-In Jack Screws (in the Flanges) or with Flange Spreaders (Look it up). Now with the Flanges spread …China and Europe remain the most important electric vehicle markets. Electric vehicles (EVs for short) are no longer just cool toys reserved for wealthy futurists. They are becomin...LIVERPOOL, England (AP) — Liverpool was denied a last-minute penalty after fighting back to draw 1-1 with Manchester City on Sunday in the final Premier League …All the handrails have to meet the requirements. Loading one side vs the other side is really irrelevant to the handrails and its connections. If there is some loading you are concerned about the in the elements supporting the handrails you might want to consider the loading on each of them simultaneously or perhaps just one side.

Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search Of All Posts, And More... Register now while it ... As a foundry engineer in a Aluminnum foundry we fight this with customers all the time. #1- Aluminum has roughly 1/2 the Brinell of iron ( hardness) thiss means if you used 6 - 3/8X16 x 1 bolts on a iron part you better look at. using 10 1/2 x 13 x 1.5 in aluminum. We also push Heli coils.One World Pharma News: This is the News-site for the company One World Pharma on Markets Insider Indices Commodities Currencies Stocks Storage tank engineering. (6881 members) forum1452 - Professional forum and technical support for engineers for Storage tank engineering. Includes problem solving collaboration tools. Search. Existing 2 storey 40+ yr old house all walls as 4" brick exterior with 4" block backup, with bond bricks turned every 7th course. I believe that this is considered as an …

Update: My final solution was to drill and epoxy #3 bars at 24" OC (every 3 CMU courses) with 18" of embedment into the existing walls. However, there was an ice storm in late December that revealed more structural problems with the building only to be exacerbated by the winter storm from February.hybrid steel/CLT structure. I'm looking to get a better understanding of using CLT deck with gyp concrete topping, supported by steel beams and columns for a five story institutional building. Specifically, what to pay attention to when using the CLT as a floor diaphragm sending lateral forces to concrete shear walls or braced frames for the LFRS.

Normally gauges and transmitters come in 1/2 " size. I've not seen many 1/2" flanges used. My standard is to have a flanged isolation valve ,1" often with a 2" tee off the main line and a reducer for mechanical integrity, with a tapped blank flange.The new search is useless, but hopefully the features of the legacy search will be reinstated soon. CWB1 (Mechanical) 28 Jan 24 16:22. I usually have better luck applying search codes like "site:eng-tips.com" in a commercial search engine like google, duckduckgo, etc rather than version of those same engines that are on the websites …From raising minimum wages to "staple green cards." The allocation of H-1B visas is very inefficient, with the lottery system being used in the years with the greatest visa demand—...*Eng-Tips's functionality depends on members receiving e-mail. By joining you are opting in to receive e-mail. Posting Guidelines. Promoting, selling, recruiting, coursework and thesis posting is forbidden. Students Click Here. Eng-Tips Posting Policies Contact US. Home > Forum Areas Geotechnical Engineers Area. Only the top forums under each heading is …Not every workplace makeover needs to involve a spending spree at Ikea and more LEDs than a flight control panel. Today's featured workspace just needed a little tidying and cable ... Safety Relief Valve engineering (PSV) (8427 members) forum1203 - Professional forum and technical support for engineers for Safety Relief Valve engineering (PSV). Includes problem solving collaboration tools. Forum. I have modelled a pond with an outlet control structure consisting of a low flow orifice (Flowing to Device 1) and sharp crested weir (Also flowing to Device 1) discharging to a culvert (Modelled as the Primary). The report states that the weir and the orifice are controlling the flows and the culvert passes XXX of XXX …

Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search …

To ask an engineering question please visit our forum site at Eng-Tips. Browse our archive of questions and answers below or to access our old forum database of over 10000 questions and answers please visit the old Ask@ forum. Forums; Search; Unanswered; Active Topics; Engineering Questions and Answers: Forums: Topics: Replies: Last Post: …

How to Improve Myself. (48697 members) forum731 - Professional forum and technical support for engineers for How to Improve Myself. Includes problem solving collaboration tools. Search.We calculate the rms value of fault current (If) at the onset of it (t=0sec), using subtransient values of reactances for the sources and taking no account of the dc component. Then, the make current is : 2.55*If. and break current is : 1.255*If. with dc component included in both cases. dpc (Electrical) 23 Jan 02 …The answer can be found in a textbook or your lecture notes from school. Shear design formulas in EC2 are based on strut-and-tie models, and when the distance of the critical section is "d" or less than that, a large part of the shear is transferred by arch action (a compression strut) directly to the support.The current ASME VIII require you to obtain U stamp certification from the ASME Board. They will issue to you, based on extensive testing of your design and fabrication capability, experience and understanding of the current ASME code requirements. No specific PD 5500 requirements. Please note that this month is …GENEVA (11 March 2024) — Syria is experiencing a wave of violence not seen since 2020, the UN Syria Commission of Inquiry warned in a report released today. …From raising minimum wages to "staple green cards." The allocation of H-1B visas is very inefficient, with the lottery system being used in the years with the greatest visa demand—...The underlying soils are saturated clayey sand soils (SC). The fill material is a slightly silty sand (-200=12 to 15%) with a modified proctor of 119 pcf and 11% moisture. We have two feet of fill in above the wet clayey soils (SC). The fill material was tested to be at 96 to 98% compaction of the modified proctor …*Eng-Tips's functionality depends on members receiving e-mail. By joining you are opting in to receive e-mail. Posting Guidelines. Promoting, selling, recruiting, coursework and thesis posting is forbidden. Students Click Here. Eng-Tips Posting Policies Contact US. Home; Forums; Structural Engineers; Activities; Welding, Bonding & Fastener … Ignition, Combustion and Detonation engineering. Laser engineering. Mechanical Seal engineering. Mechanical Acoustics/Vibration engineering. Optical systems engineering. Pipelines, Piping and Fluid Mechanics engineering. Pump engineering. Storage tank engineering. Valve engineering. See thread507-434895: Tension Field Action - End panels in Old Codes. BA. rb1957 (Aerospace) 7 Sep 20 22:16. the author makes the point that the end bays usually don't have the stiffener at the extreme end of the beam, and so the web cannot develop the shear buckles. In the example R13 posted these end panels aren't doing anything to react the ...Eng-Tips aims to support students’ professional and academic development. Engineering information and connections for the global community of engineers. Find engineering …

Efficiency (measured in stiffness or strength per unit of weight) is not highest with compact sections - it is actually quite the opposite. Class 3 sections, for example, rarely require transverse or longitudinal stiffeners, but the larger web depth acquired with them far offsets any issues relating to elastic section capacity or local buckling.Structural engineering general discussion. (83014 members) forum507 - Professional forum and technical support for engineers for Structural engineering general discussion. Includes problem solving collaboration tools.Although not directly applicable for stacks TIA/EIA-222 'Structural Standards For Steel Antenna Towers And Supporting Structures' states "Initial tension in the guys, for design purposes, is normally 10 percent of the published breaking strength of the strand with upper and lower limits of 15 and 8 percent …Instagram:https://instagram. how late is save a lot opensafelite starting paygrainger cleaning supplieswalgreens aa batteries The U.S. Department of Health and Human Services (HHS) is aware that Change Healthcare – a unit of UnitedHealth Group (UHG) – was impacted by a …From raising minimum wages to "staple green cards." The allocation of H-1B visas is very inefficient, with the lottery system being used in the years with the greatest visa demand—... hot flixxx tampa adult video store and arcade and theatersproducts offered by bob's discount furniture and mattress store erie Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search Of All Posts, And More... Register now while it ... hampton kurtz funeral homes obituaries Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search Of All Posts, And More... Register now while it ... My 1937 copy of Trautwines Civil Engineers Reference Book gives: "Normal reinforcing steel ultimate strength of between 50,000 - 70,000 lbs per sq in with elastic limit (yield) at 25,000 - 35,000 lbs per sq in. Cold working the bars will raise the elastic limit to 40,000 - 50,000 lbs per sq in. Deformed bars have a higher elastic limit claimed ...i have got into trouble with linear gap element. My model like flange contact have 500000 dof. i use linear gap method in axial direction and rbe2 (Fy~Mz) in other direction. unfurtunately, i just obtain some fatal message "fatal message 1012" no matter what i do. (try to change buffsize) or wirte down "nastran system (1015)=1".